Computers & Chemical Engineering, Vol.26, No.12, 1661-1676, 2002
Pressure drop considerations for heat exchanger network grassroots design
Pressure drop is an important issue in design of a heat exchanger network (HEN), which has yet to be addressed properly. To overcome pressure losses incurred when streams flow through heat exchangers, pumps/compressors must be installed. The total cost for a system of pumps and compressors consists of the purchase cost of equipment and the electricity cost to run these equipment. This cost could occupy a significant part of the overall cost for a HEN design. Therefore, the pressure drop aspect should be considered together with the costs for heat exchanger area and utility consumption. A new approach is proposed to consider the pressure drop aspect in the overall context of a HEN design. Firstly, the optimal DeltaT(min) is determined through three-way trade-offs between area, utility and pressure drop at the targeting stage. As a result of targeting, targets for area, utility and pressure drops can be established ahead of the network design. Then a network structure is initialised at the determined DeltaT(min) and optimised to achieve a final design. In this procedure, the pressure drop is considered at both the targeting stage and the design stage in a systematic manner.