화학공학소재연구정보센터
Combustion Science and Technology, Vol.175, No.11, 1979-2014, 2003
Gas-particle flow and combustionin the near-burner zone of the swirl-stabilized pulverized coal burner
In an air-particle test facility, a three-dimensional particle-dynamics anemometer was used to measure air particle flows in the near-burner region of the radial bias combustion burner. With the increase of nonswirling secondary air (SA) ratio, the air and the particle divergent angles greatly decrease. Both the diameter and the length of the central recirculation zone decrease and the peak value of particle volume flux near the burner axis increases. The reacting flow experiment shows that oxygen concentration decreases while CO and NOx concentrations increase in the burner central zone when the nonswirling SA ratio increases. The application of the nonswirling jet of the secondary combustion air results in a substantial reduction in carbon-in-ash content.