화학공학소재연구정보센터
Fluid Phase Equilibria, Vol.216, No.1, 85-93, 2004
Dew points of binary carbon dioxide plus water and ternary carbon dioxide plus water plus methanol mixtures - Measurement and modelling
Dew points for four carbon dioxide + water mixtures between 1.2 x 10(5) and 41.1 x 10(5) Pa in the temperature range from 251.9 to 288.2 K, and eight carbon dioxide + water + methanol mixtures between 1.2 x 10(5) and 43.5 x 10(5) Pa and temperatures from 246.0 to 289.0 K were experimentally determined. The experimental results obtained on the binary and ternary systems were analysed in terms of a predictive excess function-equation of state (EF-EOS) method, which reproduced the experimental dew point temperature data with absolute average deviation (AAD) between 0.8 and 1.8 K for the systems with water, and from 0.0 to 2.7 K for the systems with water and methanol. The experimental results obtained for carbon dioxide + water mixtures, with molar fraction of water lower than 0.00174, at pressure values higher than 5 x 10(5) Pa were also compared to a predictive equation of state model. It reproduced experimental dew point temperature data with AAD between 0.2 and 0.6 K. (C) 2003 Elsevier B.V. All rights reserved.