International Journal of Heat and Mass Transfer, Vol.47, No.24, 5351-5364, 2004
Flow structure of subcooled boiling flow in an internally heated annulus
Local measurements of flow parameters were performed for vertical upward subcooled boiling flows in an internally heated annulus. The annulus channel consisted of an inner heater rod with a diameter of 19.1 mm and an outer round pipe with an inner diameter of 38.1 mm, and the hydraulic equivalent diameter was 19.1 mm. The double-sensor conductivity probe method was used for measuring local void fraction, interfacial area concentration, and interfacial velocity. A total of 11 data were acquired consisting of four inlet liquid velocities, 0.500, 0.664, 0.987 and 1.22 m/s and two inlet liquid temperatures, 95.0 and 98.0 degreesC. The constitutive equations for distributon parameter and drift velocity in the drift-flux model, and the semi-theoretical correlation for Sauter mean diameter, namely, interfacial area concentration, which were proposed previously, were validated by local flow parameters obtained in the experiment. (C) 2004 Elsevier Ltd. All rights reserved.
Keywords:void fraction;interfacial area concentration;drift-flux model;subcooled boiling flow;multiphase flow;internally heated annulus