International Journal of Heat and Mass Transfer, Vol.48, No.25-26, 5255-5269, 2005
Heat transfer and film-cooling for the endwall of a first stage turbine vane
Secondary flows that result in turbomachines from inherent pressure gradients in airfoil passages, are the main contributors to aerodynamic losses and high heat transfer to the airfoil endwalls. The endwalls present a challenge to durability engineers in maintaining the integrity of the airfoils. One means of preventing degradation in the turbine is to film-cool components whereby coolant is extracted from the compressor and injected through small cooling holes in the airfoil surfaces. In addition to film-cooling, leakage flows from component interfaces, such as the combustor and turbine, can provide cooling in localized areas but also provide a change to the inlet boundary condition to the passage. This paper presents measurements relevant to the endwall region of a vane, which indicate the importance of considering the inlet flow condition. (c) 2005 Elsevier Ltd. All rights reserved.