화학공학소재연구정보센터
Chinese Journal of Chemical Engineering, Vol.7, No.2, 166-172, 1999
Measurement of isoplethic vapor-liquid equilibrium data by using inclined ebulliometer
Isoplethic VLE data for the systems benzene-hexane at 9 different compositions in the temperature range from 298K to 331K, chloroform-benzene at 11 different compositions in the temperature range from 308K to 350K and chloroform-hexane at 9 different compositions in the temperature range from 311K to 337K were determined by using an inclined ebulliometer with a pump-like stirrer. Isothermal and isobaric VLE were calculated from the isoplethic results with a extended UNIQUAC equation and these data agree well with the literature data.