- Previous Article
- Next Article
- Table of Contents
Journal of Hazardous Materials, Vol.124, No.1-3, 247-254, 2005
Arsenic removal via electrocoagulation from heavy metal contaminated groundwater in La Comarca Lagunera Mexico
Arsenic contamination is an enormous worldwide problem. A large number of people dwelling in Comarca Lagunera, situated in the central part of northern Mexico, use well water with arsenic in excess of the water standard regulated by the Secretary of Environment and Natural Resources of Mexico (SEMARNAT), to be suitable for human health. Individuals with lifetime exposure to arsenic develop the classic symptoms of arsenic poisoning. Among several options available for removal of arsenic from well water, electrocoagulation (EC) is a very promising electrochemical treatment technique that does not require the addition of chemicals or regeneration. First, this study will provide an introduction to the fundamental concepts of the EC method. In this study, powder X-ray diffraction, scanning electron microscopy, transmission Mossbauer spectroscopy and Fourier transform infrared spectroscopy were used to characterize the solid products formed at iron electrodes during the EC process. The results suggest that magnetite particles and amorphous iron oxyhydroxides present in the EC products remove arsenic(III) and arsenic(V) with an efficiency of more than 99% from groundwater in a field pilot scale study. (c) 2005 Elsevier B.V. All rights reserved.