Journal of Hazardous Materials, Vol.142, No.3, 647-652, 2007
Thermal characteristics of lysine tri-isocyanate and its mixture with water
The thermal reactivity of lysine tri-isocyanate (LTI, 2-isocyanatoethyl-2,6-diisocyanato caproylate) and its mixture with 1% water was investigated after the occurrence of a runaway reaction at a plant. By using a sensitive thermal calorimeter, C80, and an adiabatic calorimeter, ARC, an onset reaction of LTI was observed at 70-100 degrees C and it became vigorous at 175-200 degrees C. The reaction is considered as co-polymerization at this stage, which causes a second decomposition reaction at 200 degrees C if the heat generation is accumulated in the vessel. On the other hand, the presence of water can catalyze LTI at much lower onset temperature and lead to a moderate reaction at 50 degrees C since carbamine is produced and in turn it induces decarbonization of the LTI molecule with significant release of CO, gas which was detected by a gas chromatography and an FT-IR gas analyzer. (c) 2006 Elsevier B. V. All rights reserved.
Keywords:LTI (lysine tri-isocyanate;2-isocyanatoethyl-2,6-diisocyanato caproylate);water contamination;thermal calorimeter;gas release