화학공학소재연구정보센터
Applied Microbiology and Biotechnology, Vol.75, No.3, 685-691, 2007
Oxygen diffusion and consumption in active aerobic granules of heterogeneous structure
The interior structure of aerobic granules is highly heterogeneous, hence, affecting the transport and reaction processes in the granules. The granule structure and the dissolved oxygen profiles were probed at the same granule in the current work for possible estimation of transport and kinetic parameters in the granule. With the tested granules fed by phenol or acetate as carbon source, most inflow oxygen was consumed by an active layer thickness of less than 125 mu m on the granule surface. The confocal laser scanning microscopy scans also revealed a surface layer thickness of approximately 100 mu m consisting of cells. The diffusivities of oxygen transport and the kinetic constant of oxygen consumption in the active layers only were evaluated. The theoretical models adopted in literature that ignored the contributions of the layered structure of aerobic granule could have overlooked the possible limitations on oxygen transport.