Chemical Engineering & Technology, Vol.30, No.12, 1726-1731, 2007
Determining cyclone particle holdup by pressure drop for a CFB boiler
An experimental study was conducted to assess the possibility of determining particle holdup by measuring the pressure drop of a conventional cyclone used in a circulating fluidized bed (CFB) boiler. It was found that within a wide range of inlet solid concentrations, i.e., 0.54-4.42 kg/kg-gas, the cyclone pressure drop increased linearly with inlet solid concentration at a given gas velocity, while the pressure drop between the dust exit and the vortex finder of the cyclone remained almost constant. Since particle holdup increases virtually linearly with solid flow rate, the particle holdup in the cyclone can be derived from the cyclone pressure drop, and therefore, an equation set was proposed to calculate the particle holdup from the cyclone pressure drop.