화학공학소재연구정보센터
Color Research and Application, Vol.33, No.2, 100-107, 2008
Uncertainty analysis for the NIST 0 : 45 reflectometer
Sets of color tiles are available from the National Institute of Standards and Technology calibrated using the NIST 0:45 Reflectometer. The uncertainties associated with the measured values for the color tiles are an indispensable component of the calibration report that accompanies these tiles. A systematic, analytical approach developed previously was applied to the particular case of the reference instrument and color tile set, taking into account the operation and characteristics of the instrument and the spectral properties of the set. The primary sources of uncertainty were identified, and the resulting un certain ties in the color space values L*, a*, and b* were determined. In general, the uncertainties are lowest for those color tiles whose reflectance factors are nearly constant with wavelength. Published in 2008 by John Wiley & Sons, Inc.