Energy Conversion and Management, Vol.49, No.8, 2006-2015, 2008
Laminar mixed convection heat transfer in a vertical circular tube under buoyancy-assisted and opposed flows
Laminar mixed convection heat transfer for assisted and opposed air flows in the entrance region of a vertical circular tube with the using of a uniform wall heat flux boundary condition has been experimentally investigated. The experimental setup was designed for determining the effect of flow direction and the effect of tube inclination on the surface temperature, local and average Nusselt numbers with Reynolds number ranged from 400 to 1600 and Grashof number from 2.0 x 10(5) to 6.2 x 10(6). it was found that the circumferential surface temperature along the dimensionless tube length for opposed flow would be higher than that both of assisted flow and horizontal tube [Mohammed HA, Salman YK Experimental investigation of combined convection heat transfer for thermally developing flow in a horizontal circular cylinder. Appi Therm Eng 2007;27(8-9):1522-33.1 due to the stronger free convective currents within the cross-section. The Nusselt number values would be lower for opposed flow than that for assisted flow. It was inferred that the behaviour of Nu, for opposed flow to be strongly dependent on the combination of Re and Gr numbers. Empirical equations expressing the average Nusselt numbers in terms of Grashof and Reynolds numbers were proposed for both assisted and opposed flow cases. The average heat transfer results were compared with previous literature and showed similar trend and satisfactory agreement. (c) 2008 Elsevier Ltd. All rights reserved.
Keywords:mixed convection;buoyancy opposed flow;buoyancy-assisted flow;vertical circular tube;empirical correlations