Energy Conversion and Management, Vol.49, No.10, 2522-2529, 2008
Performance analysis of small-scale experimental facility of TWDEC
The objective of the present paper is to analyze small-scale experimental facilities of TWDEC (Travelling Wave type Direct Energy Converter) and to propose a modification in regard to a measuring device of the facilities by means of numerical simulation with the axisymmetrical two-dimensional approximation (a PIC method). The numerical simulation has given the following results: (1) tendency of the numerical results agree with the experimental results on the measured deceleration efficiency, (2) the deceleration efficiency measured in the experiment will increase if the radius of Faraday cup installed in the experiment increases and (3) the wave of condensation and rarefaction of measured electric charge density, which is averaged in the r-direction below the radius of Faraday cup, is not formed enough with a small radius of Faraday cup because of the r component of electric field which is induced by the electrode geometry. (C) 2008 Elsevier Ltd. All rights reserved.
Keywords:direct energy conversion;Travelling Wave;wave of condensation and rarefaction;radius of Faraday cup;r component of electric field;electrode geometry