화학공학소재연구정보센터
International Journal of Heat and Mass Transfer, Vol.51, No.21-22, 5269-5278, 2008
Effects of high subcooling on two-phase spray cooling and critical heat flux
Experiments were performed with FC-77 using three full-cone spray nozzles to assess the influence of subcooling on spray performance and critical heat flux (CHF) from a 1.0 x 1.0 cm(2) test surface. The relatively high boiling point of FC-77 (97 degrees C at one atmosphere) enabled testing at relatively high levels of subcooling. Increasing the subcooling delayed the onset of boiling but decreased the slope of the nucleate boiling region of the spray boiling curve. The enhancement in CHIF was relatively mild at low subcooling and more appreciable at high subcooling. CHIF was enhanced by about a 100% when subcooling was increased from 22 to 70 degrees C, reaching values as high as 349 W/cm(2). The FC-77 data were combined with prior spray CHF data from several studies into a broad CHIF database encompassing different nozzles, fluids, flow rates, spray orientations, and subcoolings. The entire CHIF database was used to modify the effect of subcooling in a previous CHIF correlation that was developed for relatively low subcoolings. The modified correlation shows excellent predictive capability. (C) 2008 Elsevier Ltd. All rights reserved.