화학공학소재연구정보센터
Journal of Chemical Thermodynamics, Vol.42, No.2, 244-250, 2010
Effect of the reference solution in the measurement of ion activity coefficients using cells with transference at T=298.15 K
This work reports individual activity coefficients of ions at T = 298.15 K in aqueous solutions obtained from voltage values of the respective half-cell ion-selective-electrode and a single-junction Ag-AgCl reference electrode, filled with different reference solutions at different concentrations. For potassium and chloride ions in KCl aqueous solutions, reference solutions of KCl, NaCl, or CsCl were used. For sodium and chloride ions in aqueous NaCl solutions, reference solutions of CsCl were used. Experimental runs were performed at molalities (1, 2, and 3) m of the reference solution. The concentration of the sample solution was increased, starting from around 1 . 10(-3) m, up to the molality of the reference solution. The values of activity coefficients are calculated using the Henderson equation to estimate the liquid-junction potential. Results show that the ionic activity coefficients are independent of the nature and concentration of reference solution. (C) 2009 Elsevier Ltd. All rights reserved.