화학공학소재연구정보센터
Thermochimica Acta, Vol.495, No.1-2, 95-100, 2009
Combustion measurement of thermoacoustic oscillating flames by diode-laser absorption spectroscopy sensors
Diode-laser absorption spectroscopy has been applied to a swirl-stabilized turbulent combustor to detect high frequency combustion oscillation and combustion state related to combustion noise. Two diode-laser absorption spectroscopy techniques of scanned-wavelength method and fixed-wavelength method are adopted. In the scanned-wavelength method, fluctuations of temperature and H2O mole fraction up to 1 kHz are detected. Two dominant peak frequencies of power spectra of these fluctuations, which are about 125 Hz and 140 Hz, coincide with those of pressure fluctuation in the combustor. In the case of control by secondary fuel injection, the energy at peak frequency of temperature and H2O mole fraction decreases in accordance with noise reduction. Similar to the combustion noise, temperature fluctuation shows a minimal Value at the appropriate frequency of secondary fuel injection. By analysing transmitted signals, the fixed-wavelength method provides power spectra similar to those obtained by the scanned-wavelength method. The advantage of the fixed-wavelength method is capability of detection of high frequency combustion oscillation more than 1 kHz. These results prove that the diode-laser absorption spectroscopy has great applicability as sensors for the combustion measurement of thermoacoustic oscillating flames and active control of turbulent combustion. (C) 2009 Elsevier B.V. All rights reserved.