화학공학소재연구정보센터
Industrial & Engineering Chemistry Research, Vol.49, No.14, 6287-6290, 2010
The Determination of Sodium Silicate Composition Using ATR FT-IR
A procedure that measures both the silica concentration and the ratio of silica to alkali content of the commercially important sodium silicate solutions using an ATR FT-IR spectrophotomer has been developed. The accuracy and precision have been found to be equal to or better than the commonly used measures via titrimetry and density determination.