화학공학소재연구정보센터
International Journal of Heat and Mass Transfer, Vol.53, No.9-10, 2143-2148, 2010
Optimization of capillary structures for inverted meniscus evaporators of loop heat pipes and heat switches
Loop heat pipes (LHPs) and other two-phase heat transfer devices are used in the thermal management of electronic devices with high density of heat dissipation. In these two-phase thermal devices, the key component is the capillary structure (CS) that pumps the working fluid using the capillary forces generated by the meniscus, which are formed due to evaporation The evaporator's performance depends greatly oil the internal structure and external configurations of the CS However, there is not enough experimental and theoretical data on the optimization of the capillary structures of evaporators. This paper covers some important aspects of the CS design for evaporators working in an "inverted meniscus" scheme and proposes a methodology for analysis and selection of the CS pores size for LHP, flat heat pipes and heat switches, aiming for maximum heat transport capacity. Based oil this methodology, two examples of capillary evaporators have been designed and evaluated. (C) 2010 Elsevier Ltd. All rights reserved.