Journal of Hazardous Materials, Vol.179, No.1-3, 840-844, 2010
H-point standard addition method applied to simultaneous kinetic determination of antimony(III) and antimony(V) by adsorptive linear sweep voltammetry
In this work, the applicability of H-point standard addition method (HPSAM) to the kinetic voltammetry data is verified. For this purpose, a procedure is described for the determination of Sb(III) and Sb(V) by adsorptive linear sweep voltammetry using pyrogallol as a complexing agent. The method is based on the differences between the rate of complexation of pyrogallol with Sb(V) and Sb(III) at pH 1.2. The results show that the H-point standard addition method is suitable for the speciation of antimony. Sb(III) and Sb(V) can be determined in the ranges of 0.003-0.120 and 0.010-0.240 mu g mL(-1), respectively. Moreover, the solution is analyzed for any possible effects of foreign ions. The obtained results show that the HPSAM in combination to electroanalytical techniques is a powerful method with high sensitivity and selectivity. The procedure is successfully applied to the speciation of antimony in water samples. (C) 2010 Elsevier B.V. All rights reserved.