화학공학소재연구정보센터
Desalination, Vol.264, No.3, 193-200, 2010
Removal of As(V) by PVDF hollow fibers membrane contactors using Aliquat-336 as extractant
In this work the removal of As(V) from an aqueous stream by non-dispersive solvent extraction in a hollow fibre membrane contactor was investigated To this purpose microporous hydrophobic poly(vinylidene fluoride) hollow fibres were prepared by the dry/wet spinning technique Fibres were spun changing the pore forming additives to obtain micro-porous sponge-like structure membranes with pore diameters of about 0 2 mu m and porosity of 80% The produced fibres were used to perform As(V) extraction experiments in a membrane contactor device using Aliquat-336 as extractant Different tests were carried out in order to study the effect of temperature initial concentration pH of the feed solution and membrane properties The results showed that the extraction of As(V) by non dispersive solvent extraction was influenced by the pH of the feed with an optimum reached for neutral values increased with the arsenic content in the feed and was not affected by temperature The extraction was favoured by working with thinner membranes The highest removal of arsenic achieved was around 70% after 6 h of operation The produced fibres kept their performance for all the experimental activity giving reproducible results with time (C) 2010 Elsevier B V All rights reserved