화학공학소재연구정보센터
Electrochemical and Solid State Letters, Vol.14, No.2, B20-B22, 2011
Glass-Forming Exogenous Silicon Contamination in Solid Oxide Fuel Cell Cathodes
Spatially resolved analyses, by energy-dispersive X-ray spectroscopy (EDS) and scanning electron microscopy, allowed the quantification of exogenous Si contamination in a solid oxide fuel cell (SOFC) cathode after operation. The Si quantification, taking into account the endogenous Si impurity level, correlated well with the expectation from the condensation of Si(OH)(4) vapor, originating from upstream alloy components and saturated in the hot inlet air. At higher resolution, EDS-transmission electron microscopy pointed out the deposition of Si vapor in the form of amorphous SiO2, blocking oxygen incorporation into the electrolyte phase within a composite SOFC cathode. (c) 2010 The Electrochemical Society. [DOI: 10.1149/1.3516622] All rights