Electrochimica Acta, Vol.56, No.5, 2411-2419, 2011
Electrochemical behavior of folic acid on mercury meniscus modified silver solid amalgam electrode
Voltammetric behavior of folic acid and folates has been investigated using direct current voltammetry, differential pulse voltammetry and adsorptive stripping differential pulse voltammetry at a mercury meniscus modified silver solid amalgam electrode (m-AgSAE). The optimum conditions have been found for their determination in a 1:9 mixture of methanol and aqueous acetate buffer, with the limit of detection about 0.5 nmol L-1. RSD at this concentration level amounted to less than 4%. Practical applicability of the newly developed method was verified by analysis of three vitamin preparations and of two multivitamin juices. (C) 2010 Elsevier Ltd. All rights reserved.
Keywords:Folic acid;Vitamins;Voltammetry;Mercury meniscus modified silver solid;amalgam electrode;Hanging mercury drop electrode