화학공학소재연구정보센터
Journal of Membrane Science, Vol.366, No.1-2, 278-285, 2011
Influence of type and pore size of membranes on cross flow microfiltration of biological suspension
Pressure driven membrane processes have been substantially used for the separation of solids and liquid. The main disadvantage of such systems is rapid fouling, causing higher energy consumption and lower flux output. The main objective of this study was to explore the influences of type and pore size of membranes on bio-fouling by biological suspensions. Cellulose acetate, polyethersulfone, mixed ester, polycarbonate (CA, PES, ME, PC) membranes with three different pore sizes (0.40-0.45, 0.22, 0.10 mu m) were used in cross flow microfiltration experiments. The flux decline behavior was observed with time. Permeate samples were taken for protein and carbohydrate analysis. Surface roughness of clean and fouled membranes were determined using atomic force microscopy (AFM) images. CA membrane with pore size of 0.45 mu m showed the most rapid decline in the flux among all membranes due to its irregular and rough surface. ME membranes yielded the greatest steady state flux value followed by PC and PES, while CA membranes had the lowest steady state flux. PC membranes had the greatest pore resistance (R(p)) for membranes at all pore sizes. Concentration polarization was observed to be a significant fouling mechanism for all membranes. (C) 2010 Elsevier B.V. All rights reserved.