화학공학소재연구정보센터
International Journal of Heat and Mass Transfer, Vol.38, No.11, 2029-2037, 1995
Calibration of a Photographic Method for Imaging Mass-Transfer in Aqueous-Solutions
We previously described a method utilizing the flow of developer solution over an exposed photographic film for imaging mass uptake patterns at solid surfaces. We have now formulated a calibration equation that converts optical density of the developed black-and-white him to the local mass transfer coefficient. This equation was evaluated with measurements of mass transfer at the surface of a spinning disk and in the entry region of a straight tube. The product of developer dilution and development time dictated the broadest range of measurable mass transfer coefficient values and had an optimum value of approximately 1.0 min.