화학공학소재연구정보센터
International Journal of Heat and Mass Transfer, Vol.40, No.17, 4007-4019, 1997
Effects of Heater Surface Orientation on the Critical Heat-Flux .1. An Experimental Evaluation of Models for Subcooled Pool Boiling
An experimental study of boiling at high heat fluxes in low-velocity subcooled forced convection boiling is presented, demonstrating the effects of subcooling and buoyancy orientation on the critical heat flux (CHF) and the bubble residence time. At the low velocity of 0.04 m s(-1) used, the flow forces acting on the vapor are insignificant compared with buoyancy and the CHF behaves as in pool boiling, depending primarily on the orientation of the heater surface with respect to gravity. This dependence is related to the bubble residence time, which is found to be inversely proportional to the CHF for all heater orientations at a given operating condition. This relationship, that the product of the CHF and the corresponding bubble residence time is a constant, suggests that the mechanism for dryout is independent of the heater surface orientation, despite changes in the vapor departure velocity and the CHF with the orientation angle. Furthermore, increases in the bulk liquid subcooling substantially reduce the net rate of vapor generation such that the bubble residence times at the CHF are independent of subcooling. The work concludes by proposing the energy per unit area leaving the heater surface during the bubble residence time as the CHF mechanism, which is more generalized than the mechanism assumed in the macrolayer dryout models.