화학공학소재연구정보센터
Bioresource Technology, Vol.100, No.14, 3663-3668, 2009
Kinetic studies of overlapping pyrolysis reactions in industrial waste activated sludge
A sludge pyrolytic kinetics model was established in this study. Two types of sewage sludge from different industrial wastewater treatment plant produced different DTG (Derivative Thermogravimetry) shapes with an overlapping pattern. The multi-heating rate method was conducted to evaluate the kinetics for obtaining reasonable pyrolysis mechanisms and DTG curves were divided into several peaks using the Lorentz fitting method based on the composition of the sludge and the desire for precision. The peaks formed corresponded to the pyrolysis reactions of volatile matter, microbe cells, proteins, inorganic substances and char respectively, which can be reasonably explained based on the results from the flue gas analyzer and the chemical analysis. Two types of sewage sludge were found to have similar pyrolysis mechanisms. Reasonable reasons were also given to explain the distortion and lag observed in the DTG curves and pyrolysis mechanism. (C) 2009 Elsevier Ltd. All rights reserved.