학회 | 한국화학공학회 |
학술대회 | 2009년 가을 (10/22 ~ 10/23, 일산 KINTEX) |
권호 | 15권 2호, p.2371 |
발표분야 | 촉매 및 반응공학 |
제목 | Constructed wetland for the non-point source management |
초록 | A specially designed constructed wetland was employed in order to treat a polluted river water in Korea. The specially designed wetland was composed of two tanks connected in series; The one is the aerobic tank, and the other is the anoxic one. The aerobic tank could be remained aerobic due to the continuous supply of air through a natural air draft system whose driving force for air supply was the difference between the temperature of the air inside the tank and the ambient air. On the bases of the results obtained from the five different pilot plant experiments, the optimum real scale constructed wetland was designed and installed to treat 1,000m3 polluted water every day. The wetland was operated for 28 months.The target concentrations of the effluent from the wetland were 2.0mg/L BOD(influent BOD 35mg/L), 3.0mg/L COD(influent COD 25mg/L), 1.0mg/L SS(influent SS 37mg/L), 3.0mg/L T-N(influent T-N 8.0mg/L) and 0.15mg/L T-P(influent T-P 1.4mg/L), respectively. About 1,000m2 area of the aerobic and anoxic tank was necessary satisfy the targeted concentration of the effluent steadily upto 28 month continuous operation without blockage of the beds. |
저자 | 김둘선, 김태한, 이영경, 레넥 투안, 조미정, 이동근 |
소속 | 경상대 |
키워드 | constructed wetland; aerobic tank; Polluted water |
원문파일 | 초록 보기 |