화학공학소재연구정보센터
학회 한국화학공학회
학술대회 2001년 가을 (10/19 ~ 10/20, 한밭대학교)
권호 7권 2호, p.4487
발표분야 에너지/환경
제목 Coalex탄과 국내 무연탄 혼소시의 연소 특성
초록 KEPRI has a pilot-scale combustion test facility, which can offer versatile tools to study coal-related impacts on utility boiler operations. The facility, a scale-down model of an existing boiler, consists of all the necessary components for the boiler except steam generation component. Various test probes are installed to monitor pulverizer performance, slagging, fouling, heat transfer, and pollutant emission, etc. Also, it incorporates the advanced boiler technologies such as flue gas recirculation, direct sorbent injection for desulfurization, electrostatic precipitator, and wet scrubber. Flow fields in the furnace can be controlled by varying the swirl number and by changing the burner configurations from single-wall to opposed-wall or corner firing mode. In this paper, combustion test results of blends of bituminous and anthracite coals are presented. In this test, combustion characteristics in terms of unburned carbon, NOx, SOx, fouling, and temperature profile as functions of coal fineness and excess air ratio were evaluated.
저자 김성철, 이현동, 김태형, 김영주, 박권순
소속 전력(연)
키워드 Combustion characteristics; Test facility Coalex coal; Anthracite coal
E-Mail ,
원문파일 초록 보기