화학공학소재연구정보센터
학회 한국화학공학회
학술대회 2015년 가을 (10/21 ~ 10/23, 일산 KINTEX)
권호 21권 2호, p.1670
발표분야 분리기술
제목 Moment Analysis of Lysozyme in Cation Exchange Chromatography
초록 Parameters of lysozyme separation in CE-HPLC (WCX-300 HENENCHEM) were calculated by moment analysis from experiment data. 30 mM sodium phosphate buffer (pH 9) was used for equilibrium. The buffer containing NaCl (0.5, 0.75, 1.0 M) eluted lysozyme. Concentrations of lysozyme were in the range of 3, 5, and 7 mg/ml. The column is with the size of 4.6*250 mm. Flow velocity was varied from 0.5 to 1.5 mL/min. Moment analysis was conducted using GR (general rate) model. Equilibrium constants (K) read to be 13.8, 12.8, and 11.9 for 0.5, 0.75 and 1.0 M salt. After the molecular diffusivity was obtained by using Wilke-Chang equation, the axial dispersion coefficient was calculated as 4.22 to 10.29 ☓〖10〗^(-5)  〖cm〗^2/s. The external mass transfer coefficients were obtained as 0.131, 0.128, and 0.125 by using Wilson-Geankoplis equation. The intra-particle diffusivity was calculated by comparing theoretical plate number and van Deemter equation. The values were from 1.74 to 8.56 ☓〖10〗^(-8)  〖cm〗^2/s. Influence on overall Htotal by each mass transfer phenomenon was also determined by calculating Hax, Hf, and Hd.
저자 김인호, 고관영
소속 충남대
키워드 Moment Analysis; General rate model; Lysozyme
E-Mail