화학공학소재연구정보센터
학회 한국고분자학회
학술대회 2008년 가을 (10/09 ~ 10/10, 일산킨텍스)
권호 33권 2호
발표분야 의료용 고분자 부문위원회
제목 Effect of Ultrasound on Peripheral Nerve RegenerationUsing PLGA/Pluronic F127 Nerve Guide Conduit
초록 The causes of nerve injury have been referred to traffic accidents, tumor damages, viral infections and the side effects of neurosurgery. Their sufficient functional recovery is considered as one of the common clinical problems. In our previous study, we observed that the asymmetrically porous PLGA/Pluronic F127 nerve guide conduit (NGC) developed by our laboratory can provide good environment for nerve regeneration. In this study, we applied ultrasound at the PLGA/F127 NGC-implanted site transcutaneously for more enhanced nerve regeneration. The PLGA/F127 NGC-implanted animals (sciatic nerve defect of rats; defect size, 10 mm) were received ultrasound at a frequency of 1 MHz and intensity 0.4 W/cm2 for 2 min with different stimulation patterns. Their nerve regeneration behaviors were compared with the control (PLGA/F127 NGC without ultrasound) and normal nerve by histological observations (Toluidine blue staining and TEM).
저자 박상철1, 오세행1, 김진만2, 이진호1
소속 1한남대, 2충남대
키워드 Ultrasound; nerve regeneration; nerve guide conduit
E-Mail