학회 | 한국화학공학회 |
학술대회 | 2003년 봄 (04/25 ~ 04/26, 순천대학교) |
권호 | 9권 1호, p.365 |
발표분야 | 분리기술 |
제목 | 과포화도 측정용 수정진동자의 응용 |
초록 | The degree of supersaturation is an important measure for the operation of crystallization processes, because it is directly related to the control of crystal size distribution and shape. A conventional technique utilizing solution composition and temperature has a variety of problems caused from the measurement error and the handling of analyzing samples. A direct measurement system of the supersaturation using a quartz crystal sensor is proposed here, and its performance is examined applying different manipulations of coolant temperature. The experimental outcome and photographic examination indicate that the measurements of resonant frequency and resistance of the sensor can be used for the prediction of the formation and growth of solid crystal from the crystallization process. The direct measurement system eliminates the intrinsic error source of the conventional system to give the improved measurement and on-line application availability. |
저자 | 김병철, 정옥진, 김영한 |
소속 | 동아대 |
키워드 | 결정화; 과포화도; 직접측정; 수정진동자 |
, , | |
원문파일 | 초록 보기 |