화학공학소재연구정보센터
학회 한국화학공학회
학술대회 2004년 봄 (04/23 ~ 04/24, 공주대학교)
권호 10권 1호, p.231
발표분야 분리기술
제목 산소공장 전처리 흡착탑의 최적 탈착조건 Pilot Plant 테스트 결과
초록 The optimum operation condition for molecular sieve adsorption tower of cryogenic oxygen plant to save the energy cost were studied by using a pilot scale temperature swing adsorption tower.
In this study, the effective adsorption capacity and pore properties of commercially available active alumina and MS-13X were measured and characterized.
The desorption profiles of CO2 was measured at various regeneration temperature.
For the regeneration of MS-13X ,CO2 was almost desorpted at 110℃ .
This temperature was lower as 30℃ than that of operation condition at real plant.
By installation and operation of by-pass line during the cooling cycle of regeneration of adsorption tower, electric energy could be saved as 422kWh/cycle and saved the operation cost.
저자 김제영, 홍익표
소속 포항산업과학(연)
키워드 TSA; CO2; H2O
E-Mail
원문파일 초록 보기