학회 |
한국화학공학회 |
학술대회 |
2014년 봄 (04/23 ~ 04/25, 창원컨벤션센터) |
권호 |
20권 1호, p.634 |
발표분야 |
유동층 |
제목 |
Relationship between solid flow rate and riser pressure drop in high pressure circulating fluidized bed |
초록 |
A study was conducted at high pressure system to identify a method to predict solid flow rate from riser pressure drop in a circulating fluidized bed, whose riser is 0.025m-ID and 2.75m-high. Experiments were carried out at different pressures (1 to 5 bar) and different standard state superficial gas velocities (150-400 cm/s. Glass beads and spent FCC having 54.5 and 92 μm specific surface mean diameter, 2440 and 2250 kg/m3 density respectively were used. Information on riser pressure drop, solid flow rate were systematically investigated at elevated pressures. Effect of riser and loop seal aeration on solid flow rate at high pressure was also studied. An equation was developed to predict solid circulation rate at high pressure conditions, from riser pressure drop. |
저자 |
Muhammad Shahzad Khurram1, 최정후1, 원유섭1, 나석호1, 류호정2
|
소속 |
1건국대, 2한국에너지기술(연) |
키워드 |
High pressure; Circulating fluidized bed; Riser pressre drop; Loop seal; Superficial gas
|
E-Mail |
|
VOD |
VOD 보기 |
원문파일 |
초록 보기 |