초록 |
The effects of the operating conditions in AFC single cells have not been studied in detail. In this study, by using a one-dimensional isothermal model a computational simulation was conducted to investigate the effects of the initial electrolyte concentration and the operating gas pressure. According to the result, the optimum electrolyte concentration at the base-case was found to be within 3.0 M - 3.5 M. The variation of the cell performance according to the electrolyte concentration was found to be caused mainly by the charge transfer resistances of both electrodes, Henry’s constant and the liquid phase diffusivity of the dissolved gases. It was also found that an increase in operating pressure increased the reaction rates and the solubilities of the gases, which led to a considerable enhancement of the cell performance.
|