화학공학소재연구정보센터
학회 한국화학공학회
학술대회 2004년 가을 (10/29 ~ 10/30, 호서대학교(아산캠퍼스))
권호 10권 2호, p.1447
발표분야 분리기술
제목 Evaluation of Membrane Fouling Index for Secondary Wastewater
초록 The performance of membrane operation is often reduced because of concentration polarization and fouling, which causes continuous flux decline. Fouling phenomena have been characterized by using many parameters such as the silting index, plugging index, fouling index and membrane filtration index. The general limitation of these methods is the requirement of long time. Hence, studies were carried out to minimize the time required to evaluate the fouling index by combining the pressure variation and effluent volume obtained for short time, under various operating conditions including powdered activated carbon dose, permeate flow rate, pH of the feed solution, feed temperature etc. Results showed that flux decline for secondary domestic wastewater was highly dependent on the powdered activated carbon dose. Especially, the proposed method considerably reduced the measuring time for determining the fouling index.
저자 류동완1, 김태원1, 이대행2, 이재욱3, 문 희1
소속 1전남대, 2광주광역시 보건환경(연), 3서남대
키워드 membrane. fouling; wastewater; PAC
E-Mail
원문파일 초록 보기