화학공학소재연구정보센터
Applied Chemistry, Vol.3, No.2, 156-159, October, 1999
지르코늄의 트리튬 저장을 위한 수소흡수 예비실험
Preliminary Experiment on the H2 Absorption of Zirconium for Titium Storage
A hydrogen absorption apparatus was installed for the experiment of hydrogen absorption as a basic procedure for the tritium immobilization. The basic experiment on the hydrogen absorption was conducted by using the zircaloy scrap and the sponge. The surface of the zircaloy scrap was activated and the equilibrium time on hydrogen absorption was determined. Morphology change of the zircaloy scrap was observed according to the progress of activation. The value of H/M measured under the hydrogen condition of 46 atm showed about 2.04 at 600℃ in case of the zircaloy scrap and about 2.01 at 400℃ in case of the zirconium sponge, respectively. These values were maximum allowable hydrogen storage capacity in zirconium.