Chinese Journal of Chemical Engineering, Vol.8, No.3, 247-250, 2000
Computational modeling of tangentially fired boiler (II) NOx emissions
The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOx formation mechanism model, along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.